ACCURACY OF METAL ARTIFACT REDUCTION ALGORITHM OF CONE BEAM COMPUTED TOMOGRAPHY IN IDENTIFICATION OF FRACTURED ENDODONTIC FILES (A DIAGNOSTIC ACCURACY STUDY) | ||||
Alexandria Dental Journal | ||||
Article 10, Volume 47, Issue 2, August 2022, Page 70-76 PDF (253.75 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/adjalexu.2022.106438.1231 | ||||
![]() | ||||
Authors | ||||
Sara Ibrahim Madian ![]() ![]() ![]() | ||||
1Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology department, Faculty of Dentistry, Alexandria University, Alexandria, Egypt | ||||
2Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology. Department of Oral Medicine, Periodontology, Oral Diagnosis and Oral Radiology, Faculty of Dentistry, Alexandria University, Alexandria, Egypt | ||||
3Oral and Maxillofacial Radiology, Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ain Shams University, Cairo, Egypt | ||||
4Department of Conservative Dentistry, Faculty of Dentistry, Alexandria University, Alexandria, Egypt | ||||
Abstract | ||||
Introduction: A separated instrument in the root canal may compromise adequate treatment of the entire root canal system. Radiographic detection of retained instruments is a very important step for proper treatment planning. Cone Beam Computed Tomography (CBCT) scans provide three-dimensional (3D) imaging of maxillofacial anatomy. Yet, the presence of canal filling in close proximity to a fractured instrument may cause beam hardening artifacts in CBCT images that may reduce the diagnostic accuracy. So that, the need for Metal artifact reduction (MAR) tool is mandatory to improve image quality. Objectives: The purpose of this study was to assess the accuracy of the MAR tool of CBCT in the detection of separated endodontic instruments in root canals. Methodology: One hundred forty-four canals of mandibular molar teeth were divided into four groups: the control group having empty canals, the fracture group with a fractured file fragment, the fill group with gutta-percha points, and the fill/fracture group that was filled with presence of a fractured file fragment. The teeth were radiographed by CBCT with MAR tool application and periapical X-Ray using complementary metal oxide semiconductor (CMOS) sensor to evaluate the diagnostic accuracy of both techniques in the identification of the separated fragment. Results: In the presence of filling, periapical radiography showed greater diagnostic accuracy than CBCT with MAR tool activation. In the absence of filling, there was no statistically significant difference between the two radiographic techniques. Conclusions: Periapical radiography is the best technique for detection of fractured instruments in filled and unfilled root canals. | ||||
Keywords | ||||
Beam hardening artifact; Cone beam computed tomography; Metal artifact reduction tool; Separated instrument | ||||
Statistics Article View: 267 PDF Download: 432 |
||||