THE USE OF WIRE STRAIN GAGES TO DETECT SOME TYPES OF SPLITTING FAILURE IN NOTCHED COMPOSITES | ||
International Conference on Aerospace Sciences and Aviation Technology | ||
Article 19, Volume 5, ASAT CONFERENCE 4 - 6 May 1993, CAIRO, May 1993, Pages 231-241 PDF (2.63 M) | ||
Document Type: Original Article | ||
DOI: 10.21608/asat.1993.25625 | ||
Author | ||
Hatem H. DAKEN | ||
Assist Professor of Mechanical Design and Head, Design with Innovative Materials Group, Military Technical College, Cairo, EGYPT. | ||
Abstract | ||
Two experimental investigations have demonstrated the extreme usefulness of using wire strain gages in studying the mechanical behavior of com-posites. Wire strain gages have also shown their capacity in detecting some splitting failure types in notched composites under tensile loads. The first investigation entailed notched [07 8 unidirectional graphite/epoxy composites. An arrangement of wire strain gages around the notch boundary has easily detected the onset ofsplitting damage in the specimen. Splitting damage is through-the-thickness matrix cracks emanating from the notch tips and propagating along the filament direction. The second investigation entailed notched [0/145°Js graphite/epoxy laminates. Splitting damage in both the 0° and 45° plies have been identified using a modified gage arrangement. | ||
Statistics Article View: 200 PDF Download: 277 |