Effect of CAD/CAM zirconia versus cast metal attachment on stresses induced in Kennedy class I cases ( Strain gauge analysis) | ||||
Ain Shams Dental Journal | ||||
Article 4, Volume 30, Issue 2, June 2023, Page 6-12 PDF (1.22 MB) | ||||
Document Type: Original articles | ||||
DOI: 10.21608/asdj.2022.139651.1122 | ||||
![]() | ||||
Authors | ||||
maha abdel monsef shokr ![]() ![]() ![]() | ||||
1prosthodontics, faculty of dentistry, Modern university for technology and information, Cairo, Egypt | ||||
2professor of prosthodontics, prosthodontics department, faculty of dentistry, ain shams university | ||||
3associate professor of prosthodontics, prosthodontics department, faculty of dentistry, ain shams university, Egypt | ||||
4professor of prosthodontics, department of prosthodontics, faculty of dentistry, Cairo University, Cairo, Egypt | ||||
Abstract | ||||
ABSTRACT Background: The removable partial denture (RPD) continues to be an essential prosthetic consideration especially when edentulous ridges posterior to a patient’s remaining teeth are to be restored. Precision attachments are used as extra-coronal retainers which are characterized by considerable retention improvement. In the current study, we aim to assess strains develop in supporting structures of two study groups resembling Kennedy class I partially edentulous cases which are rehabilitated with Co-Cr cast metal and CAD/CAM milled zirconia successively. Objective: To evaluate the effect of two different extra-coronal attachments, (Co-Cr cast metal and CAD/CAM milled zirconia) on stresses induced in supporting structure in Kennedy class I cases. Materials and Methods: This in vitro study was conducted on partially edentulous Kennedy class I cases. Two materials used in the construction of extra-coronal attachment retaining removable partial dentures were investigated; cast Co-Cr and CAD/CAM milled zirconia. The stresses induced were evaluated using the electric strain gauge analysis technique. Results: evaluating the strains developed in both groups showed a statistically significant increase in stresses induced in the group rehabilitated with Co-Cr cast metal attachments compared to the group of CAD/CAM milled zirconia on the loaded side and a statistically insignificant difference in the unloaded side. Conclusion: CAD/CAM milled zirconia and Co-Cr cast metal attachments showed a different distribution of forces as the zirconia attachment transmits fewer stresses to the loaded and unloaded sides compared to the metal attachment. Keywords: Removable partial denture, Extra-coronal attachments, CAD/CAM zirconia | ||||
Keywords | ||||
Removable partial denture; Extra-coronal attachments; CAD/CAM zirconia | ||||
Statistics Article View: 331 PDF Download: 357 |
||||