Comparison of Cyclic Fatigue Resistance of Two Different Rotary NiTi Instruments (An In-Vitro Study) | ||
| Ain Shams Dental Journal | ||
| Volume 33, Issue 1, March 2024, Pages 121-126 PDF (1.22 M) | ||
| Document Type: Original articles | ||
| DOI: 10.21608/asdj.2023.216874.1180 | ||
| Authors | ||
| Dalia Abd elmoez Abd allah* 1; mohamed Nagy2; Tariq Yehia3 | ||
| 1Endodontics Department , ASU | ||
| 2Endodontics Department, Faculty of Dentistry, Ain shams University | ||
| 3EndodonticS Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt. | ||
| Abstract | ||
| Aim: The aim of this study was to compare the dynamic cyclic fatigue resistance of M3-ProGold files and Pepsi Gold Files. Materials and methods: Eighty files of size 25/.06 of M3 Pro Gold files and Pepsi Gold files (each n = 40) were evaluated for dynamic cyclic fatigue resistance inside two artificial stainless steel canals with 2 different radii [(60 curvature, 3 mm radius) and (60 curvature, 5 mm radius)] at body temperature while submerged in distilled water at 37 ° ± 1 °C. The NCF (number of cycles to failure) was calculated. The data of NCF were analyzed using ANOVA and Tukey post hoc tests (P ≤ 0 .05). Results: The Pepsi Gold files had a significantly higher number of cycles to failure than the M3 Pro Gold files in both canal radii at body temperature. Conclusion: Pepsi Gold files have greater resistance to cyclic fatigue than M3 Pro Gold files. | ||
| Keywords | ||
| Cyclic Fatigue; CM-Alloy; M3 Pro Gold files; Pepsi Gold files | ||
|
Statistics Article View: 382 PDF Download: 486 |
||