Assessment of Atrial Electromechanical Delay Using Tissue Doppler Echocardiography in Children with Asthma | ||||
Benha Medical Journal | ||||
Article 4, Volume 42, Issue 7, July 2025, Page 720-729 PDF (683.35 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/bmfj.2025.336471.2254 | ||||
![]() | ||||
Authors | ||||
Somaia Abdelsamie Elwan1; Ahmed Abdelsadek Mohamed2; Alaa Elsayed Abd elghane Elsayad ![]() ![]() | ||||
1Department of Pediatric , Faculty of Medicine–Benha University, Benha, Egypt. | ||||
2Department of chest diseases , Faculty of Medicine–Benha University, Benha, Egypt. | ||||
3Department of Pediatric , Damanhour General hospital, Faculty of Medicine, University of Tanta. | ||||
Abstract | ||||
Background: Electrocardiographic abnormalities are common in asthma. Atrial electromechanical delay (AED) was assessed atrial conduction properties and used to predict risks of arrhythmias in bronchial asthma using tissue doppler echocardiography. The aim of: this work was to assess AED using tissue doppler echocardiography in children with asthma. Methods: This case control study was carried out on 40 asthmatic children aged from 8 to 16 years old, both sexes, diagnosed with asthma, suggested by periodic symptoms of chest tightness, dysnea and wheezing responding to bronchodilator asthma therapy (case group) and 40 healthy children as (control group). History, physical examination, Conventional echocardiographic and tissue doppler assessment including atrial electromechanical delay and myocardial performance index (MPI) ws performed for both group. Results: The dimension of right atrium (RA), P-wave dispersion (PWD), isovolumic contraction time (ICT), isovolumic relaxation time (IRT), ET, MPI, right ventricular (RV) pulmonary atresia, intra-right atrial conduction time (IRCT) and inter-atrial conduction time (IACT) was significantly higher in the asthmatic group (p < 0.05). IRCT and IACT were significantly higher in the asthmatic group. There was a significant positive correlation between IRCT with age, severity of asthma, duration of illness, ICT and IRT while significant negative correlation between IRCT with PEFR. There was a significant positive correlation between IACT with Tricuspid S and MPI while significant negative correlation between IACT with PEFR. Conclusions: Asthmatic children were associated with higher RA dimension, impaired RV function, higher IRCT and IACT. There was a positive correlation between IRCT and PWD, PEFR and MPI. | ||||
Keywords | ||||
Atrial Electromechanical Delay; Tissue Doppler Echocardiography; Children; Asthma | ||||
Statistics Article View: 98 PDF Download: 80 |
||||