Validity and Reliability of Modified Sphygmomanometer Versus Jamar Dynamometer in Measuring Hand Grip Strength for Patients with Distal Radius Fractures | ||||
The Medical Journal of Cairo University | ||||
Volume 92, Issue 12, December 2024, Page 1225-1232 PDF (207.18 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/mjcu.2024.411634 | ||||
![]() | ||||
Author | ||||
EMAN H. ANWAR, M.Sc.*; SALWA F. ABD EL MAJEED, Ph.D.*; MOHAMED E. SHALABY, Ph.D.** and EMAD A. ABDEL ATI, M.D.*** | ||||
The Department of Science of Physical Therapy for Musculoskeletal Disorder and its Surgery, Faculty of Physical Therapy, Cairo University*, Orthopedic Physical Therapy, Faculty of Physical Therapy, Cairo University** and Orthopedics Department, Faculty of Medicine, Cairo University*** | ||||
Abstract | ||||
Abstract Background: The modified sphygmomanometer and Jamar grip dynamometer are important tools to measure the hand grip strength (HGS). Aim of Study: Is to test the concurrent validity, interrater and test-retest reliability of bag modified sphygmomanometer and Jamar grip dynamometer. Subjects and Methods: Seventy patients of distal radi-us fracture (67 colles’ and 3 smith fracture) with mean age 45.03±10.45 years, were recruited to evaluate the grip strength by Jamar grip dynamometer and bag modified sphygmoma-nometer after being updated with the aneroid sphygmomanom-eter (KBM). Validity was explained by the correlation between the strength of hand grip that was assessed by modified sphyg-momanometer and Jamar dynamometer by Person Correlation Coefficient. Test-retest reliability and inter-rater reliability were expressed as Intra-class Correlation Coefficients (ICCs). All data was analyzed by (SPSS) version 25 for windows. Results: There was a correlation between strength of hand grip that was assessed by modified sphygmomanometer and Jamar dynamometer; was strong correlation with positive signif-icant in concurrent validity (r=0.852, p=0.001). The modified sphygmomanometer showed excellent in test-retest reliability with Intra-class correlation coefficient (ICC) was 0.996 and in in-ter-rater reliability with 0.993 Intra-class correlation coefficient. Conclusion: The bag modified sphygmomanometer is a concurrently valid, test-retest and interrater reliable device to measure hand grip of distal radius fracture patients with differ-ent gender and fixation types. | ||||
Keywords | ||||
Distal radius fracture; Grip dynamometer; Bag modified sphygmomanometer; Pneumatic grip in-struments; Hydraulic grip instruments | ||||
Statistics Article View: 102 PDF Download: 61 |
||||