CO2 Emissions, Green House Gas Calculations and Controlling in the Gas Plant | ||||
Egyptian Journal of Chemistry | ||||
Article 31, Volume 64, Issue 3, March 2021, Page 1421-1431 PDF (488.11 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/ejchem.2020.47850.2978 | ||||
View on SCiNiTO | ||||
Authors | ||||
Ebrahiem Esmail Ebrahiem 1; Abdelaziz Ahmed Noaman2; Tarek M Aboulfotouh3; Moustapha I Mansour4; Yassin A Hakim5 | ||||
1Chem. Eng. Dept., Faaculty of Eng., Minia university. Minia, Egypt. | ||||
2chemical engineering department, faculty of engineering, Minia university | ||||
3Mining and Petroleum Engineering Department, Faculty of Engineering, Al-Azhar University, Cairo 11884, Egypt | ||||
4Chemical Engineering Department, Faculty of Engineering, Alexandria University, Alexandria 21544, Egypt. | ||||
5Chemical Engineering Department, Faculty of Engineering, Minia University, Minia, Egypt | ||||
Abstract | ||||
Gas flaring is one of the most challenging energy and environmental problems facing the world today whether regionally or globally. Gas flaring becomes a public concern and a priority issue because it’s waste of a non-renewable source in addition to environmental problems due to gas emissions that produce greenhouse effects. Also, it represents definite risks to human health. Air emissions calculations were conducted based on the international guidelines and found that CO2 pollutant is the main source of the emissions in the gas plant, the yearly emissions of CO2 are 343.3 Ton /year. The second source of emissions in the gas plant is CH4. The yearly emissions from methane CH4 is 3.3 Ton/year. The other sources of emissions in the gas plant include CO, NOx and VOC. Total GHG emissions from the gas project Facilities during normal operation are estimated to be 55,133 Ton/year CO2 equivalents. CO2 is the main GHG pollutant, which contributes over 91% of the GHG. The calculated GHG intensity of the gas project facilities is 0.05 Tons of CO2 equivalents per ton of the total production. To minimize the emissions and GHG in the process facilities of the gas plant waste heat recovery unit must be installed, Ultra-Low NOx Burners is recommended for minimizing NOx emissions, CO2 Gas injection to the reservoir to be installed and finally the energy efficiency of the project facilities should be improved by enhancing heat integration and recovery throughout the plant | ||||
Keywords | ||||
Keyword: flared gas; emission; GHG; fired heater; CO2 injection | ||||
Statistics Article View: 517 PDF Download: 628 |
||||