BEHAVIOR OF SHEAR WALLS UNDER AXIAL LOAD AND CYCLIC LOAD | ||||
JES. Journal of Engineering Sciences | ||||
Article 1, Volume 39, No 5, September and October 2011, Page 933-946 PDF (225.01 K) | ||||
Document Type: Research Paper | ||||
DOI: 10.21608/jesaun.2011.129373 | ||||
View on SCiNiTO | ||||
Authors | ||||
Mostafa A. Osman1; F. I. Khairallah2; M. Eldemrdash3 | ||||
1Assistant Professor of Concrete, Civil Engineering Dept., Faculty of Engineering, Helwan University, Cairo, Egypt. | ||||
2Lecturer of Structural Engineering, Faculty of Engineering - Mattaria, Helwan University, Cairo, Egypt | ||||
3Professor of Properties of Materials, Faculty of Engineering - Mattaria, Helwan University, Cairo, Egypt | ||||
Abstract | ||||
Reinforced concrete walls are often introduced into multistory buildings to resist lateral forces which can be exists due to winds or earthquakes. In the present study, six models I–section shear wall models were tested under combined action of a constant axial load and reversal horizontal increased loading until failure. The study has investigated the effects of some parameters such as, the height – to – width ratio, the compressive strength of concrete, and the variation of main flexure reinforcement ratio on the behavior of high - strength concrete shear walls. The obtained results from the tests have helped to identify the causes of wall failure modes. The test results included the determination of ultimate load, deflection, mode of failure, crack pattern, ductility, stiffness, and energy absorption. | ||||
Keywords | ||||
RC design; High strength concrete; Seismic analysis; Cyclic loading | ||||
Statistics Article View: 70 PDF Download: 249 |
||||