- Yadav P, Bharath MJ, Sahadev CK, Makonahalli Ramachandra PK, Rao Y, Ali A, et al. An in vitro CT comparison of gutta-percha removal with two rotary systems and hedstrom files. Iran Endod J. 2013;8:59–64.
- Mali S, Patil A, Hegde D, Jaiswal H, Saoji H, Edake DN. Efficacy of rotary and hand instrument in removing gutta-percha and sealer from root canals of endodontically treated teeth. J Contemp Dent Pract. 2018;19:964–8.
- Bedier MM, Hashem AAR, Hassan YM. Improved dentin disinfection by combining different-geometry rotary nickel-titanium files in preparing root canals. Restor Dent Endod. 2018;43:e46.
- De-Deus G, Belladonna FG, Zuolo AS, Cavalcante DM, Carvalhal JCA, Simões-Carvalho M, et al. XP-endo Finisher R instrument optimizes the removal of root filling remnants in oval-shaped canals. Int Endod J. 2019;52:899–907.
dönmez özkan H, Kaval M, Özkan G, Özer S. Efficacy of two different nickel-titanium rotary systems in retreatment procedure with or without laser-activated irrigation: An in vitro study. Photomed Laser Surg. 2019;37:495-9.
- dönmez özkan H, Kaval M, Özkan G, Özer S. Efficacy of two different nickel-titanium rotary systems in retreatment procedure with or without laser-activated irrigation: An in vitro study. Photomed Laser Surg. 2019;37:495-9.
- Nair U, Natera M, Koscso K, Pillai P, Varella C, Pileggi R. Comparative evaluation of three different irrigation activation on debris removal from root canal systems. J. Dent. Sci.. 2011;57.
- Alzuabi MA, Abiad R. Ability of of XP-Endo Finisher and XP-Endo Finisher-R in removal of debris from the root canal walls after retreatment: An in-vitro study. Int Arab J Dent. 2018;9:61-4.
- Alturaiki S, Lamphon H, Edrees H, Ahlquist M. Efficacy of 3 different irrigation systems on removal of calcium hydroxide from the root canal: a scanning electron microscopic study. J Endod. 2015;41:97–101.
Vertucci FJ. Root canal anatomy of the human permanent teeth. Oral Surg Oral Med Oral Pathol. 1984;58:589
- Vertucci FJ. Root canal anatomy of the human permanent teeth. Oral Surg Oral Med Oral Pathol. 1984;58:589–99.
- Günday M, Sazak H, Garip Y. A comparative study of three different root canal curvature measurement techniques and measuring the canal access angle in curved canals. J Endod. 2005;31:796–8.
- Ozyurek T. Comparison of the smear layer removal ability of four different final activation techniques after retreatment procedures: a SEM investigation. Turk Endod J. 2017;2:10-6.
- Srinivasan R, Ashwathappa GS, Junjanna P, Bhandary S, Aswathanarayana RM, Shetty A. Evaluation of smear layer removal from ultrasonically prepared retrocavities by three agents. J Conserv Dent. 2014;17:330–4.
- McHugh ML. Interrater reliability: the kappa statistic. Biochem Med (Zagreb). 2012;22:276–82.
- Hammad M, Qualtrough A, Silikas N. Three-dimensional evaluation of effectiveness of hand and rotary instrumentation for retreatment of canals filled with different materials. J Endod. 2008;34:1370–3.
- Unal GC, Kaya BU, Taç AG, Keçeci AD. A comparison of the efficacy of conventional and new retreatment instruments to remove gutta-percha in curved root canals: an ex vivo study. Int Endod J. 2009;42:344–50.
- Ersev H, Yilmaz B, Dinçol ME, Dağlaroğlu R. The efficacy of ProTaper Universal rotary retreatment instrumentation to remove single gutta-percha cones cemented with several endodontic sealers. Int Endod J. 2012;45:756–62.
- Campello AF, Almeida BM, Franzoni MA, Alves FRF, Marceliano-Alves MF, Rôças IN, et al. Influence of solvent and a supplementary step with a finishing instrument on filling material removal from canals connected by an isthmus. Int Endod J. 2019;52:716–24.
- Dadresanfar B, Iranmanesh M, Mohebbi P, Vatanpour M. Efficacy of two rotary NiTi instruments in removal of resilon/epiphany obturants. Iran Endod J. 2012;7:183.
- Khedmat S, Azari A, Shamshiri AR, Fadae M, Bashizadeh Fakhar H. Efficacy of ProTaper and Mtwo Retreatment Files in Removal of Gutta-percha and GuttaFlow from Root Canals. Iran Endod J. 2016;11:184–7.
- Talal T, al-zaka I. Efficacy of XP-endo Finisher, XP-endo Finisher R, CanalBrush and endoactivator in the removal of intracanal medicament (An in vitro study). Int. J. Sci.. 2018;8:919–28.
- Silva EJNL, Belladonna FG, Zuolo AS, Rodrigues E, Ehrhardt IC, Souza EM, et al. Effectiveness of XP-endo Finisher and XP-endo Finisher R in removing root filling remnants: a micro-CT study. Int Endod J. 2018;51:86–91.
- Machado AG, Guilherme BPS, Provenzano JC, Marceliano-Alves MF, Gonçalves LS, Siqueira JF, et al. Effects of preparation with the Self-Adjusting File, TRUShape and XP-endo Shaper systems, and a supplementary step with XP-endo Finisher R on filling material removal during retreatment of mandibular molar canals. Int Endod J. 2019;52:709–15.
|