Precise Assessment of gamma absorbed dose rates using different techniques. | ||||
Arab Journal of Nuclear Sciences and Applications | ||||
Article 3, Volume 52, Issue 1, January 2019, Page 14-21 PDF (747.75 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/ajnsa.2018.2415.1031 | ||||
View on SCiNiTO | ||||
Authors | ||||
heba saudy 1; samir khamesy2; M S Garawi3 | ||||
1physics, faculty of science, Al Azhar university | ||||
2physics,faculty of science,ain shams universty | ||||
3Physics Department, Faculty of Science, King Saud University, Riyadh | ||||
Abstract | ||||
In the present work, the gamma spectroscopy technique has been applied to determine the outdoor and indoor absorbed dose due to background gamma radiations outside and inside King Saud University campus in Malaz (Girls' Branch). Also, thermoluminescence technique along with a theoretical model based on Monte Carlo simulation and point Kernel dose equation have been applied to determine the gamma rays indoor absorbed dose rates in the same place. The absorbed dose of each gamma line was calculated and estimation of the total absorbed dose for the detected gamma lines were obtained and found to 44.73 and 55.03 nG/h for outdoor and indoor respectively. Furthermore, TLD dosimeters were employed for two consecutive 60 days measuring periods. The obtained TLD results provide an estimation of outdoor and indoor average dose rates of values 45 and 63.21 nGy/h respectively. Additionally, the mean value of gamma rays indoor absorbed dose rates obtained by means of the applied theoretical model was 58.49±2.1 nGy/h. | ||||
Keywords | ||||
absorbed dose; HPGe; TLD dosimeters | ||||
Statistics Article View: 412 PDF Download: 373 |
||||