Effect of sponge Density on septic tank effluent quality for dairy wastewater treatment | ||||
Engineering Research Journal (Shoubra) | ||||
Volume 50, Issue 1, October 2021, Page 106-112 PDF (755.49 K) | ||||
Document Type: Research articles | ||||
DOI: 10.21608/erjsh.2021.226082 | ||||
View on SCiNiTO | ||||
Authors | ||||
Samar Mohamed1; Khaled Hassan2; Rehab Mohammed3 | ||||
1PhD Student Faculty of Engineering, Shoubra, Banha University, Egypt. | ||||
2Associate Professor, Higher Institute of Engineering, El Shorouk Academy, Egypt | ||||
3Associate Professor, Faculty of engineering Shoubra, Banha University, Egypt | ||||
Abstract | ||||
The aim of the study was to describe the modification of septic tank using different densities of sponge for treating dairy wastewater. The sponge used as a gravity filter media after conventional septic tank. The densities of sponge has a strong effect of total suspended solid (TSS), biochemical oxygen demand (BOD) and chemical oxygen demand (COD) efficiencies which are achieved removal efficiencies 94.96%, 79.72%, 79.19% respectively. | ||||
Statistics Article View: 91 PDF Download: 115 |
||||