Internals Design of Continuous Stirred Tank Electrochemical Reactor Based on the Residence Time Distribution Approach | ||||
Egyptian Journal of Chemistry | ||||
Volume 66, Issue 1, January 2023, Page 439-445 PDF (619.03 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/ejchem.2022.122976.5502 | ||||
View on SCiNiTO | ||||
Authors | ||||
Raghad S. Mahmood; Ammar S. Abbas | ||||
Chemical Engineering Department, College of Engineering, University of Baghdad | ||||
Abstract | ||||
The design of the reactor internals of the two-phase Continuous Stirred Tank Electrochemical Reactor (CSTER) was studied under different conditions. Two types of air distributors were tested (cubic and circular) according to the bubble size produced by each, measured by a high-speed camera. Two impeller types were tested (Rushton turbine 4 and 6 blades). The results indicate that the bubble size increases with increasing airflow, but the cubic distributor has a smaller bubble diameter than the circular distributor under all conditions. The value of average time for the 4-blades turbine was more than it for the 6-blades turbine at a lower mixing speed, but at 600 rpm, the 6-blade turbine has a value of average time closer to the ideal space-time. | ||||
Keywords | ||||
Electrochemical; advanced oxidation; reactor; hydrodynamics; bubble size; mixer | ||||
Statistics Article View: 351 PDF Download: 143 |
||||