Development HPLC technique for determining Oxymetazoline and Isoxspurine in pharmaceutical formulations | ||||
Egyptian Journal of Chemistry | ||||
Article 67, Volume 65, Issue 11, November 2022, Page 779-784 PDF (194.31 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/ejchem.2022.151275.6551 | ||||
View on SCiNiTO | ||||
Authors | ||||
Zaid Alnedawi1; Ali M Hassan1; Hind Hadi2; Ahmed Shabana1 | ||||
1Department of Chemistry, Faculty of Science, Al-Azhar University, Cairo, Egypt | ||||
2Department of Chemistry, College of Science, Baghdad University, Baghdad, Iraq | ||||
Abstract | ||||
A fast high-performance liquid chromatography method was established to estimate Oxymetazoline hydrochloride and Isoxsuprine hydrochloride in pharmaceutical preparations HPLC. It consists of an Azorbax-C8 (250mm ×4.6 mm, 5µm ) column with a mobile phase composed of methanol:acetonitrile: buffer (0.01 M) potassium dihydrogen phosphate with triethylamine (pH 5.5) (50: 10:40, V/V/V ) eluted at 1.5 ml/min flow rate. The detection was done using a photodiode array (PDA) detector. The proposed method was validated in linearity, precision, and accuracy. The retention times of IsoxsuprineHCl and OxymetazolineHCl are 3.6 and 6.2 ±0.4 min, respectively. The linear range and detection limits were 1-250 µg/ml and 0.5 µg/ml, respectively, for both drugs. The proposed method was successfully applied to determine ISX and OXY in pharmaceutical preparations. | ||||
Keywords | ||||
Oxymetazoline Hydrochloride; HPLC; Isoxsuprine Hydrochloride | ||||
Statistics Article View: 291 PDF Download: 218 |
||||