The Effect of Different Adhesive System Application Modes on Nanolekage At Superfacial And Deep Dentin After Varying Storage Interval | ||||
Al-Azhar Assiut Dental Journal | ||||
Article 12, Volume 6, Issue 1, April 2023, Page 123-135 PDF (2.39 MB) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/aadj.2023.296426 | ||||
View on SCiNiTO | ||||
Authors | ||||
Mohamed Wakwak 1; Mahmoud El-Said Ahmed Abd El-Aziz 2; Karim Sherif Adly Dewedar3; Abdelmonem Abdalla Amr4; Labib Mohammed Labib Elsebaey5 | ||||
1Department of Operative Dentistry, Faculty of Dental Medicine (Cairo-Boys), Al-Azhar University, Cairo, Egypt. | ||||
2Department of Dental Biomaterials, Faculty of Dental Medicine (Assuit), Al-Azhar University, Assuit, Egypt | ||||
3Department of Crown and bridge, Faculty of Dental Medicine (Cairo-Boys), Al-Azhar University, Cairo, Egypt. | ||||
4Department of Endodontic, Faculty of Dental Medicine (Cairo-Boys), Al-Azhar University, Cairo, Egypt | ||||
5Department of Operative Dentistry, Faculty of Dentistry, Nahada University, Beni-suief, Egypt. | ||||
Abstract | ||||
Aim: The goal of this study was to assess the nanoleakage of nano-filled resin composites utilizing various adhesive systems at varying dentin depths. Subjects and methods: In this investigation, 120 freshly removed human molars were tested. The chosen teeth were randomly divided into two main groups (n=60), with each main group being divided into two smaller groups (n=30) based on the adhesive system (etch- &rinse mode and self-etch mode of application). According to the superficial and deep < /div> dentin layers used in the adhesion process, each small group was separated into two even smaller subgroups (n = 15). Each smaller group was divided into three different categories depending on the lengths of storage (24 hours, 3 months, and 6 months) (n = 5). Each tooth was gradually reconstructed using the nanofilled resin composite. The specimens were cut longitudinally in the mesio-distal and bucco-lingual orientations to create resin-dentin beams. For the purpose of assessing nanoleakage, the beam was submerged in silver nitrate. Results: There was no statistically significant difference between groups in terms of the effect of application mode or dentin depth on nanoleakage, however there was a statistically significant increase in median nano-leakage scores from 24 hours to 3 months and 3 to 6 months of storage duration. Conclusion: The use of both bonding chemicals helps to reduce resin composite leakage. Since the self-etch adhesive system excelled total etch in deep cavities, it is advised to use it. While the total etch adhesive method, is advised for use in superficial cavities. | ||||
Keywords | ||||
Self-etch; total etch; nanofilled resin composite; Nanoleakage; SEM; G-aenial bond.parameters | ||||
Statistics Article View: 74 PDF Download: 129 |
||||