Strengthening of seismically deficient moment-resisting frames with yielding metallic damper | ||||
Delta University Scientific Journal | ||||
Volume 6, Issue 2, September 2023, Page 231-247 PDF (1.05 MB) | ||||
Document Type: Original research papers | ||||
DOI: 10.21608/dusj.2023.318652 | ||||
View on SCiNiTO | ||||
Authors | ||||
Ahmed Elgammal 1; Yasmin Ali 1; Ayman Seleemah* 2 | ||||
1Civil Engineering Department, Faculty of Engineering, Delta University for Science and Technology, Gamasa, 11152, Egypt | ||||
2Structural Engineering Department, Faculty of Engineering, Tanta University, Tanta, 31527, Egypt | ||||
Abstract | ||||
Due to the continuous development of codes of practice and design guidelines, existing moment-resisting frames might become deficient because of not satisfying the requirements of them. On the other hand, yielding metallic dampers are one of the most commonly known methods to strengthen deficient buildings to safely withstand seismic excitations. Therefore, this research presents an assessment of the seismic performance of moment-resisting frames strengthened with a particular type of yielding metallic dampers known as the “vertical shear link” using the finite element software ETABS (18.0.0). For this purpose, five-, ten-, and fifteenstory steel buildings that are designed to resist gravity loads only are installed with vertical shear links and their response is evaluated using modal, pushover, and time-history analyses. The vertical shear links are made of either steel or magnesium and they are installed in different locations throughout the buildings. Modal analysis results indicate that the installation of vertical shear links shortens the fundamental period of the buildings. Moreover, the pushover curves underscore the efficiency of vertical shear links in upgrading the performance level of the buildings. However, this does not apply for the fifteen-story building since the number of the installed vertical shear links is found to be not sufficient. Time-history analysis also confirms the same findings since, in contrast to the five- and ten-story buildings, the story displacements and interstory drifts of the fifteenstory building are not significantly decreased after strengthening. Also, the vertical shear links are found to participate in dissipating a considerable amount of seismic energy | ||||
Keywords | ||||
Strengthening; Retrofitting; Eccentrically braced frame; Shear link; Pushover analysis; Timehistory analysis | ||||