Comparing the Efficacy of Two-Dimensional Ultrasound and Three-Dimensional Power Doppler for Diagnosing Placenta Accreta Spectrum Disorders and Predicting Complications: A Prospective Cross-Sectional Study. | ||||
Minia Journal of Medical Research | ||||
Articles in Press, Accepted Manuscript, Available Online from 24 January 2024 | ||||
Document Type: Original Article | ||||
DOI: 10.21608/mjmr.2024.260318.1602 | ||||
View on SCiNiTO | ||||
Authors | ||||
Mohamed Mahmoud Soltan 1; AHMAD ABDELMALEK2; Hany Kamel Hassan3; Saad El Gelany 4; Mohamed Ahmed Mohamed5 | ||||
1Obstetric and gynecology department, faculty of medicine, Minia university, Minia, Egypt | ||||
2Obstetrics and Gynecology, faculty of medicine, Minia university, Minia, Egypt | ||||
3Obstetrics and Gynecology department Faculty of medicine Minia university Mallawi Minia | ||||
4Obstetrics and Gynecology, Faculty of Medicine – Minia University, Egypt. | ||||
5Obstetrics and Gynecology, Faculty of Medicine – Minia University, Egypt | ||||
Abstract | ||||
Background: Placenta accreta spectrum (PAS) issue has become a noteworthy dangerous obstetrical issue because of its expanded rate from 0.12 to 0.31% in the last 30 years and the detailed death of roughly 7.0%. Objectives: To compare between the two-dimensional ultrasound and three-dimensional power Doppler for diagnosis of Placenta accrete spectrum disorders and prediction of its complications. Patients and methods: This was a prospective cross sectional single-institute study carried out on 86 patients suspected to have PAS-disorders by Two dimensional ultrasound 2D US and color Doppler during ANC at Obstetrics and Gynecology department, Minia maternity University Hospital from July 2021 to July 2022. Results: There was highly statistically significant difference as regards histopathology findings of 2D US (MAP, Non-MAP and Total) P<0. 001. VI, FI, and VFI were significantly higher among patients with MAP compared to patients without P<0. 001. The 2D US sensitivity was 87.3%, specificity was 90.3%, NPV was 80% and PPV was 94.1% with accuracy of 88.4% in diagnosis of MAP. 70.9% of the patients suffered from hemorrhage, 6.9% suffered from bladder injury, 10.5% reported preterm birth, and 3.5% suffered from bowel injury. Conclusion: 3D power Doppler can be used as a complementary technique to 2D ultrasound for confirmation of the diagnosis of placental invasion owing to its high sensitivity. | ||||
Keywords | ||||
Two dimensional ultrasound; three-dimensional power Doppler; Placenta accrete spectrum disorders | ||||
Statistics Article View: 48 |
||||