The Role Of Whole-Body SPECT/CT Using Tc-99m MDP In Characterization Of Osseous Lesions In Breast Cancer Patients | ||||
Egyptian Journal Nuclear Medicine | ||||
Volume 24, Issue 1, June 2022, Page 52-64 PDF (688.27 K) | ||||
Document Type: Original Paper, Diagnostic NM | ||||
DOI: 10.21608/egyjnm.2022.126177.1051 | ||||
![]() | ||||
Authors | ||||
Mohammed O Osman ![]() ![]() | ||||
1Oncology and nuclear medicine department, Kasr Alainy, Cairo University | ||||
2Nuclear Medicine Department Kasr Alainy Cairo University | ||||
3Nuclear Medicine Department, Kasr Alainy Cairo University | ||||
4Nuclear Medicine Kasr Alainy Cairo University | ||||
Abstract | ||||
Introduction: breast cancer is the second greatest cause of death in women, affecting women of all ages, races, and geographical locations [1]. Bone, lungs, and liver are the most common locations of distant metastases [2]. The most extensively used approach for detecting bone metastases is whole-body bone scintigraphy with technetium99m tagged diphosphonates [4]. Objectives: Compare the rate of detectability of bone metastases in breast cancer patients utilizing whole body single photon emission computed tomography/ computed tomography against planar conventional bone scintigraphy. Material and methods: prospective study included 50 female patients diagnosed with breast cancer, with an average age of 46.9 ± 15 years. Planar bone scintigraphy was performed on the patients, followed by whole body SPECT/CT scans by administering 1110 MBq of Tc99m MDP intravenously. Full body scan was performed (table rate 12 cm/min). A total of 32 frames with 15 seconds per frame were used to collect SPECT and CT images of the entire body over a 360-degree arc with a 128*128 matrix and iterative filtration (four iterations, four subsets, and Gaussian filter 8). Both modalities were read independently by two competent nuclear medicine experts. Results: The sensitivity, specificity, positive predictive value, and negative predictive value of Planar bone scintigraphy and W.B. SPECT/CT images were 52.2 % Vs 87 %, 92.6 % Vs 96.3 %, 85.7 % Vs 95.2 %, and 69.4 % Vs 89.7 %, respectively. The difference in sensitivity between the two modalities was statistically significant (P-value = 0.001), whereas the difference in specificity was statistically inconsequential (P-value = 0.5). Conclusions: whole-body SPECT/CT bone scintigraphy improves the sensitivity of the bone scan for detecting osseous metastases and minimizes the number of equivocal lesions. | ||||
Keywords | ||||
Keywords: Bone metastases; Planar bone scintigraphy; Whole-body SPECT/CT bone | ||||
Statistics Article View: 26 PDF Download: 12 |
||||