Comparative Study of the Retention of an OT Equator with Smart Boxes Versus Novaloc Attachment for Mandibular Implant-Assisted Overdentures (In Vitro Study) | ||||
Egyptian Dental Journal | ||||
Volume 71, Issue 1 - Serial Number 4, January 2025, Page 681-694 PDF (1.31 MB) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/edj.2024.336526.3261 | ||||
![]() | ||||
Authors | ||||
Rim Adel Selima ![]() ![]() ![]() ![]() ![]() | ||||
1MSD, Master’s Degree of Prosthodontics and Implantology, Prosthodontic Department, Faculty of Dentistry, Pharos University, Alexandria, Egypt. | ||||
2Associate Professor of Prosthodontics, Faculty of Dentistry, Pharos University, Alexandria, Egypt | ||||
3BDS, Faculty of Dentistry, Pharos University, Alexandria, Egypt | ||||
4Associate Professor of Prosthodontics, Faculty of Dentistry, Pharos University. Alexandria, Egypt | ||||
Abstract | ||||
Background: Implant-supported mandibular overdentures have many advantages over conventional complete dentures; therefore, they have become the first alternative choice for treating patients with completely edentulous ridges. One of the most important advantages of implant-supported mandibular overdentures is superior retention, which eliminates the fear of detachment during surgery. This superior retention is due to the presence of alternative well-known attachment systems that may result in lower maintenance needs and other favorable characteristics. One of the alternatives is a new type of attachment dubbed Novaloc, based on mechanical retention from a poly-ether-ether-ketone (Peek) matrix on a cylindrical patrix, which may be more resistant to wear than the nylon used in other systems. Materials & Method: This in vitro study was carried out on a mandibular completely edentulous cast with two mandibular implants in the cuspid region bilaterally. The casts were divided into 2 equal groups: (Group A) an OT Equator with Smart Box Attachment and (Group B) a Novaloc attachment. Sixteen overdentures were subjected to 540 cyclic loads. The retention of the attachments was recorded as a baseline and after 270 and 540 cycles, respectively, which is equivalent to 6 months of simulation. Results: The study revealed a significant decrease in the mean retention force in group I (Ot Equator with Smart Box) at baseline, after 270 cycles (3 months), and after 540 cycles (6 months). Conclusions: The OT-Equator with a Smart Box Attachment group had better initial retentive force than the Novaloc attachment group with a medium retentive cap. | ||||
Keywords | ||||
Nonparallel implants; Equator (smart box) attachment; Novaloc attachment; Overdenture | ||||
Statistics Article View: 176 PDF Download: 103 |
||||