- Brunski JB. Biomechanical factors are affecting the bone-dental implant interface. Clin Mater. 1992;10:153-201.
- Elias CN, Oshida Y, Lima JHC, Muller CA. The relationship between surface properties (roughness, wettability, and morphology) of titanium and dental implant removal torque. J Mech Behav Biomed Mater. 2008;1:234-42.
- Martin C, Thoms, G, Melo ACM, Fontúo FK. The peri-implant bone response following immediate implants placed in the esthetic zone and with immediate provisionalization--a case series study. Oral Maxillofac Surg. 2015;19:157-63.
- Park JC, Lee JW, Kim SM, Lee JH. Implant stabilityMeasuring devices and randomized clinical trial for ISQ value change pattern measured from two different directions by magnetic RFA. InTech 2011;5:111-29.
- Junker R, Dimakis A, Thoneick M, Jansen JA. Effects of implant surface coatings and composition on bone integration: a systematic review. Clin Oral Implants Res. 2009;20:185-206.
- Ohnhaus EE, Adler R. Methodological problems in the measurement of pain: a comparison between the verbal rating scale and the visual analog scale. Pain. 1975;1:379-84.
- Closs SJ, Barr B, Briggs M, Cash K, Seers K. A comparison of five pain assessment scales for nursing home residents with varying degrees of cognitive impairment. J Pain Symptom Manage. 2004;27:196- 205.
- Carlsson AM. Assessment of chronic pain. I. Aspects of the reliability and validity of the visual analog scale. Pain. 1983;16:87-101.
- Rodriguez CS. Pain measurement in the elderly: a review. Pain Manag Nurs. 2001;2:38-46.
- Lobene RR, Weatherford T, Ross NM, Lamm RA, Menaker L. A modified gingival index for use in clinical trials. Clin Prev Dent.1986;8:3-6.
- Löe H. The gingival index, the plaque index and the retention index systems. J Periodontol. 1967;38:610- 6.
- Khan SN, Warkhedkar RM, Shyam AK. Analysis of the Hounsfield unit of human bones for strength evaluation. Procedia Mater. Sci. 2014;6:512-9.
- Mendoza G, Mendoza DB, Aragao FJ, Cooper LF. Advancing dental implant surface technology--from micron-to nanotopography. Biomaterials. 2008;29:3822-35.
- Misch CE, Perel ML, Wang HL, Sammartino G, Galindo-Moreno P, Trisi P, et al. Implant success, survival, and failure: the International Congress of Oral Implantologists (ICOI) Pisa consensus conference. Implant Dent. 2008;17:5-15.
- Bain CA, Moy PK. The association between the failure of dental implants and cigarette smoking. Int J Oral Maxillofac Implants. 1993;8: 609-15.
- Schmitt A, Zarb GA. The longitudinal clinical effectiveness of osseointegrated dental implants for single-tooth replacement. Int J Prosthodont. 1993;6: 197-202.
- Esposito M, Coulthard P, Thomsen P, Worthington HV. The role of implant surface modifications, shape, and material on the success of osseointegrated dental implants. A Cochrane systematic review. Eur J Prosthodont Restor Dent. 2005;13: 15-31.
- Quesada-Garcia MP, Prados-Sanchez E, OlmedoGaya MV, Munoz-Soto E, Gonzílez-Rodrguez MP, Vallecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal. 2009;14:e538-e546.
- Biaggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crystal bone geometry: a three-dimensional finite element analysis. J Prosthet Dent. 2008;100:422- 31.
- Himmlova L, Dostíloví T, Kícovsk A, Konvicakov S. Influence of implant length and diameter on stress distribution: a finite element analysis. J Prosthet Dent. 2004;91:20-5.
- Miyamoto I, Tsuboi Y, Wada E, Suwa H, Iizuka T. Influence of cortical bone thickness and implant length on implant stability at the time of surgery-clinical, prospective, biomechanical, and imaging study. Bone. 2005;37:776-80.
- Iplik H, Akaok K. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone. J Dent. 2002;30:41-6.
- Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res.1991;25:889-902.
- Szmukler-Moncler S, Salama H, Reingewirtz Y, Dubruille JH. The timing of loading and effect of micromotion on bone-dental implant interface: a review of the experimental literature. J Biomed Mater Res. 1998;43:192-203.
- Garber DA. The esthetic dental implant: letting restoration be the guide. J Am Dent Assoc. 1995;126:319-25.
- Balshi TJ, Wolfinger GJ. Dental implants in the diabetic patient: a retrospective study. Implant Dent. 1999;8:355-9.
- Dixon DL, Breeding LC, Sadler JP, McKay ML. Comparison of screw loosening, rotation, and deflection among three implant designs. J Prosthet Dent. 1995;74:270-8.
- O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res. 2000;2:85-92.
- Steigenga JT, Al-Shammari KF, Nociti FH, Misch CE, Wang HL. Dental implant design and its relationship to long-term implant success. Implant Dent. 2003;12:306-17.
- dos Santos MV, Elias CN, Cavalcanti Lima JH. The effects of superficial roughness and design on the primary stability of dental implants. Clin Implant Dent Relat Res. 2011;13:215-23.
- Geng JP, Tan KB, Liu GR. Application of finite element analysis in implant dentistry: a review of the literature. J Prosthet Dent. 2001;85:585-98.
- Li T, Kong L, Wang Y, Hu K, Song L, Liu B, et al. Selection of optimal dental implant diameter and length in type IV bone: a three-dimensional finite element analysis. Int J Oral Maxillofac Surg. 2009;38:1077-83.
- Petrie CS, Williams JL. Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest: A threedimensional finite-element analysis. Clin Oral Implants Res. 2005;16:486-94.
- Sim CP, Lang NP. Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length. Clin Oral Implants Res. 2010;21:598-604.
- Bullis G, Shah S. Implant Surface Treatments: A Literature Review. Inclusive Magazine 2018;5.
- Kim DG, Shin MJ, Kim KH, Hanawa T. Surface treatments of titanium in aqueous solutions containing calcium and phosphate ions. Biomed Mater Eng. 1999;9:89-96.
- Romeo E, Lops D, Margutti E, Ghisolfi M, Chiapasco M, Vogel G. Long-term survival and success of oral implants in the treatment of full and partial arches: a 7-year prospective study with the ITI dental implant system. Int J Oral Maxillofac Implants. 2004;19: 247- 59.
- Misch CE. Dental Implant Prosthetics-E-Book. St. Louis: Elsevier Health Sciences, 2014.
- Renvert S, Roo JansÑker A, Claffey N. Nonsurgical treatment of peri-implant mucositis and periimplantitis: a literature review. J Clin Periodontol. 2008;35:305-15.
- Lang NP, Wilson TG, Corbet EF. Biological complications with dental implants: their prevention, diagnosis and treatment Note. Clin Oral Implants Res. 2000;11:146-55.
|