NICKEL ION SELECTIVE POLY VINYL CHLORIDE MEMBRANE ELECTRODE BASED ON LIX 54 | ||||
Al-Azhar Bulletin of Science | ||||
Article 4, Volume 22, Issue 2-A, December 2011, Page 37-44 PDF (145.62 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/absb.2011.7015 | ||||
View on SCiNiTO | ||||
Authors | ||||
Ali M. HASSAN* 1; SOHAIR A. ELREEFY2; AHMED R. ELSALAMOUNY3 | ||||
1Chemistry Department, Faculty of Science, Al-Azhar University, Cairo, Egypt | ||||
2Hot Labs Center, Atomic Energy Authority, Cairo, Egypt | ||||
3Chemistry Department, Faculty of Science Al-Azhar University, Cairo, Egypt | ||||
Abstract | ||||
PVC based ion selective electrode, which was selective and sensitive to Ni (II) ions, was developed using 1- phenyldecane - 1,3 - diones (LIX 54) as a carrier. The electrode exhibited a good potentiometric response for Ni (II) over a wide concentration range (1.0×10-5 – 1.0×10-1 M) with a slope 29.1 + 1.6 mV/decade. The proposed electrode has a response time about 25 s. The electrode is suitable for use in aqueous solutions in a wide pH range of 8.0 to 9.5. The proposed electrode was used in two different applications such as the determination of nickel concentration in nickel-cadmium battery and as an indicator electrode for potentiometric titration of Ni2+ion with EDTA. | ||||
Keywords | ||||
Nickel ion selective electrode; LIX 54; Potentiometry | ||||
Statistics Article View: 160 PDF Download: 268 |
||||