Experimental Study of Jet Impinging Double-Pass Solar Air Heater Using Wire-Mesh. | ||||
MEJ- Mansoura Engineering Journal | ||||
Article 13, Volume 45, Issue 3, September 2020, Page 1-8 PDF (979.75 K) | ||||
Document Type: Research Studies | ||||
DOI: 10.21608/bfemu.2020.121199 | ||||
View on SCiNiTO | ||||
Authors | ||||
Moner Moftah Atiya 1; Gamal Ibrahim Sultan2; Ahmed Abd-Elsalam Hegazi3 | ||||
1Researcher at Mechanical Engineering Department, Mansoura University, Mansoura 35516 | ||||
2a Professor at the Department of Mechanical Power Engineering, Mansoura University, Mansoura, Egypt | ||||
3Mechanical Engineering Department, University of Mansoura, CO 35516, Egypt | ||||
Abstract | ||||
This paper manages the test examination of the Solar Air Heater (SAH)exit temperature and efficiency. The trial test segment is planned and manufactured to study the jet impingement effect on the absorber plate with wire mesh, among circular jets in a channel of SAH, and compared with traditional SAH with the jet plate. The proposed solar air heater is tested by varying the nozzle diameter to have the values 3 mm, 5 mm,7 mm and 9 mm while the mass flow rate of air range is 0.0147–0.0201 kg/s. The research declared that the maximum thermal efficiency is gained at 3 mm hole ID. The maximum thermal efficiency is 72.33%with wire mesh and 61.89% without wire mesh at the mass flow rate is 0.0201 kg/s. The lowest performance is recorded at the 9 mm diameter hole. The best percentage increase in efficiency of the IJDPSAH with metal wire mesh occurs at 5 mm is 29.48%. | ||||
Keywords | ||||
Double pass solar air; Jet impingement; Wire mesh; Efficiency | ||||
Statistics Article View: 163 PDF Download: 285 |
||||