Accuracy of CBCT based computer assisted surgical guide for implant placement with tilted position in posterior atrophied mandible | ||||
Egyptian Journal of Oral and Maxillofacial Surgery | ||||
Article 1, Volume 11, Issue 3, July 2020, Page 80-88 PDF (398.19 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/omx.2021.61803.1109 | ||||
View on SCiNiTO | ||||
Authors | ||||
Enas Abdel Ghafar 1; Ghada Abdel Monim2 | ||||
1Department of Oral and Maxillofacial Radiology , Faculty of Dentistry, Cairo University, Cairo, Egypt | ||||
2Department of Oral and Maxillofacial, Faculty of Dentistry, Cairo University, Cairo, Egypt | ||||
Abstract | ||||
Purpose: Investigate the accuracy of CBCT based computer aided surgical guide CASG for implant placement in posterior atrophied mandible with tilted position (buccal or lingual) to inferior alveolar nerve IAN avoiding its injury. Materials and Methods: 15 partially edentulous patients with atrophied mandible were included based on certain eligibility criteria, the work flow in this study run as following, CBCT imaging, virtual implant planning and CASG designing, 3D stereolithographic printing of surgical guide, surgical procedures of implant placement using the CASG, post-operative CBCT imaging, registration of pre- and post-operative CBCT images, assessment of angular deviation between actual and planned implants and linear deviation between them cervically and apically, comparison between virtual and actual implants distance to IAN. Results: Wilcoxon signed-rank test Comparing between virtual and actual implants’ distance to IAN showed a statistically significant difference with a mean distance of 0.72 ± 0.25 mm for actual implants and 1.7 ± 0.56 mm for virtual implants. (4.13 ± 1.86°) was the mean angular deviation, while 1.15 ± 0.49 mm and 1.32 ± 0.63 were the mean cervical and apical linear deviation respectively. Conclusion: although a significant difference was found between virtual and actual implants distance to IAN, the values of linear and angular deviation between them were well accepted and within the range reported by most of similar clinical studies with less crucial situations, which enhance using fully guided stereolithographic CASG for implant placement with tilted position in posterior atrophied mandible but with considering at least 2 mm distance between virtual implant and IAN in planning procedures. | ||||
Keywords | ||||
Atrophied Mandible; By-pass- Computer aided surgical guide; CBCT; Dental Implants; Inferior Alveolar Nerve | ||||
Statistics Article View: 142 PDF Download: 468 |
||||