EXTENDED-STORAGE IRREVERSIBLE HYDROCOLLOID IMPRESSION MATERIALS | ||||
Alexandria Dental Journal | ||||
Article 5, Volume 41, Issue 2, August 2016, Page 146-149 PDF (458.98 K) | ||||
Document Type: Original Article | ||||
DOI: 10.21608/adjalexu.2016.59269 | ||||
View on SCiNiTO | ||||
Authors | ||||
El-Danasory Muhammed B.* ; Gad Muhammed A.* ; Hanafy Seham A.* | ||||
Instructor at the removable prosthodontics department, faculty of Dentistry, Alexandria University, Alexandria, Egypt. | ||||
Abstract | ||||
INTRODUCTION: There are many contingencies, so many dentists do not pour their own impressions immediately which clears the need for extended-storage alginate impression materials. OBJECTIVES: Evaluating and comparing three extended-storage alginate impression materials concerning their dimensional stability. MATERIALS AND METHODS: One hundred and eighty (180) specimens were prepared in accordance with ADA specification No. 18 using three extended-storage alginates; Hydrogum5 (Zhermack), Cavex ColorChange (Cavex) and Blueprint X Crème (Dentsply). Following to ADA specification No. 19 dimensional stability was evaluated directly at six intervals; 0, 24, 48, 72, 96 and 120 hours using 10 specimens/interval /material. Specimens for delayed evaluation, were stored moistened within sealed plastic bags in a dark room at 23 ±1ºc. RESULTS: All impression materials showed initial expansion and ended with a net shrinkage. Cavex ColorChange showed the least dimensional changes. Dimensional changes of Cavex ColorChange, Hydrogum5 and Blueprint Xcrème ranged (0.14 - 0.59, 0.37 - 2.07 and 0.35 - 1.40% respectively). CONCLUSION: While Cavex ColorChange can be stored up to 120 hours without clinically significant dimensional changes, Hydrogum5 and Blueprint Xcrème should be poured immediately for the best results. | ||||
Keywords | ||||
Alginate; Extended storage; Dimensional stability; Cavex ColorChange; Hydrogum5; Blueprint Xcrème | ||||
References | ||||
1. Carr AB, McGivney GP, Brown DT. McCracken's Removable partial prosthodontics, 12th ed, St. Louis: Mosby; 2010.
2. Nallamuthu NA, Braden M, Patel MP. Some aspects of the formulation of alginate dental impression materials-Setting characteristics and mechanical properties. J Dental Materials. 2012;28:756–62.
3. Dahl LB, Dymbe B, Valderhaug J. Bonding properties and dimensional stability of hydrocolloid impression systems in fixed prosthodontics. J Prosthet Dent. 1985;53:796‑800.
4. Sedda M, Casarotto A, Rausita A, Borracchini A. Effect of storage time on the accuracy of casts made from different irreversible hydrocolloids. J Contemporary Dental Practice. 2008;9:59-66.
5. Walker MP, Burckhard J, Mitts DA, Williams KB. Dimensional change over time of extended-storage alginate impression materials. Angle Orthod. 2010;80:1110-15.
6. Rodrigues SB, Augusto CR, Leitune VCB, Samuel SMW, Collares FM. Influence of delayed pouring on irreversible hydrocolloid properties. J Brazilian Oral Research (São Paulo). 2012;26:404-9.
7. Imbery TA, Nehring J, Janus C, Moon PC. Accuracy and dimensional stability of extended-pour and conventional alginate impression materials. J Am Dent Assoc. 2010;141:32-9.
8. Mosharraf R, Nosouhian S, Salehi M. Effect of storage time on dimensional stability of Extended-pour irreversible hydrocolloid impression material. J Isfahan Dental School. 2011;7:246-55.
9. Rohanian A, Shabestari GO, Zeighami S, Samadi MJ, Shamshiri AR. Effect of Storage Time of ExtendedPour and Conventional Alginate Impressions on Dimensional Accuracy of Casts. J Dentistry (Tehran). 2014;11:655-64.
10.Revised American National Standards Institute/American Dental Association, ANSI/ADA, Specification No. 18 for dental alginate impression materials, Chicago Ill: ADA; 1992.
11. American National Standard Institute/American Dental Association, ANSI/ADA, Specification No. 19 for Dental Elastomeric Impression Materials, Chicago Ill: ADA; 2004.
12. Fernandes A, Dua N, Herekar M. Corrective Primary Impression Technique. Open Dental Journal. 2010;4:27-8.
13. Kitamura A, Kawai Y. Basic investigation of the laminated alginate impression technique: Setting time, permanent deformation, elastic deformation, consistency, and tensile bond strength tests. J Prosthodontic Research. 2015;59:49-54.
14. Eriksson A, Ockert-Eriksson G, Lockowandt P. Accuracy of irreversible hydrocolloids (alginates) for fixed prosthodontics. A comparison between irreversible hydrocolloid, reversible hydrocolloid, and addition silicone for use in the syringe-tray technique. Eur J Oral Sci. 1998;106:651-60.
15.Bayramoğlu E, Özkan YK, Yildiz C. Comparison of marginal and internal fit of presson-metal and conventional ceramic systems for three- and four-unit implant-supported partial fixed dental prostheses: An in vitro study. J Prosthet Dent. 2015;114:52-8.
16. Fellows CM, Thomas GA. Determination of bound and unbound water in dental alginate irreversible hydrocolloid by nuclear magnetic resonance spectroscopy. J Dental Materials. 2009;25:486-93. | ||||
Statistics Article View: 188 PDF Download: 867 |
||||