EKB Journal Management System

1.

Radiographic Assessment of Digital Tray Technique versus Conventional Technique on the Accuracy of Mandibular Screw Retained Implant Overdentures

Pages 3291-3304
Aya Fawzy; Shady El Naggar

2.

Effect of Aging on Translucency and Flexural Strength of Different Zirconia Materials (An In-Vitro Study)

Pages 3305-3311
Amr Alzebdah; Ahmed Mohammed hamdy; Alaa Mohammed Naguib

3.

Comparing two different angulated abutment designs on marginal bone loss around divergent two implants retaining mandibular overdentures: A radiographic prospective study.

Pages 3312-3322
Marwa Mohamed

4.

Biting Force and chewing efficiency of Conventional and CAD/CAM complete dentures. A Cross-over Study

Pages 3323-3335
nourhan ragheb; Wafaa Ibrahim

5.

Correlation between the water sorption and the flexural strength in heat-cured acrylic resin with different fillers

Pages 3337-3344
Ahmad Shoeib; Ahmed Shoun

6.

Bonding of zirconia superstructure to one-piece titanium and zirconia implants with different luting agents.

Pages 3345-3354
Mahy Hassouna; Lamia Dawood

7.

Influence of dental bonding surface and bonding methods on marginal adaptation of occlusal veneer after thermal aging

Pages 3355-3363
Lamia Dawood; Walid Al-Zordk

8.

A NEW METHOD FOR ASSESSMENT OF MENTAL FORAMEN RELATED LANDMARKS USING COMPUTED TOMOGRAPHY SCAN

Pages 3365-3372
Mona Moustafa Elramady

9.

The Effect of different Surface Treatments on Shear Bond Strength of Cubic Zirconia

Pages 3373-3379
Engy Hemdan; Tarek Morsy; Fatma Mohamed

10.

Biomechanical behavior of different implant abutment materials

Pages 3381-3391
Mohamed Atif Elkholy; mohamed sedeek; waleed elshahawy; elrefaiy qenawy

11.

Effect of Different Techniques of CAD/CAM Designed BioHpp Frameworks on The Supporting Structures of Kennedy Class I Telescopic Partial Denture Cases

Pages 3393-3402
HEBA ELSARRIF; Shaimaa Mohamed; Marwa Sabet

12.

EVALUATION OF BALL TYPE PRECISION ATTACHMENT FOR LOWER CLASS I KENNEDY CLASSIFICATION USING NEW COMPUTERIZED METHOD

Pages 3403-3412
Mona Elramady

13.

Comparison Of Chair Side Time And Treatment Outcomes Of Stabilization Splints Obtained From Digital Versus Conventional Workflow

Pages 3413-3420
Amr Elkhadem; Reem Hossameldin

14.

All on four fixed prostheses versus implant overdentures for management of edentulous maxilla opposing mandibular 2- implant assisted overdentures

Pages 3421-3434
Hesham Alam; Mona Aboelnagga

15.

Three-Dimensional evaluation of marginal bone resorption associated with flap and flapless placement of immediately loaded implants retaining mandibular overdentures with resilient stud attachments. One year randomized controlled clinical trial

Pages 3435-3446
Samer Ali

16.

Probing depth and patient satisfaction with mandibular overdentures retained by four versus two mini-implants: randomized controlled clinical study

Pages 3447-3456
May Hassan; Ayman Gouda; Eman Helal

17.

Evaluation of Patient Satisfaction with Mandibular Screw Retained Hybrid Prosthesis Versus Mandibular Implant Over-Dentures Retained by Telescopic Attachments

Pages 3457-3463
Khaled Abdelwahab; MOHAMED ABDALLA

18.

Impact of Two Different Designs and Materials on Fracture Resistance of Occlusal Veneers (In Vitro Study)

Pages 3465-3473
Yasmin Elgendy; Manal Abo Madina; Nesma Elgohary

19.

Evaluation of Cervical Margin Relocation for CAD/CAM Zirconia Crowns Using Different Composite Resin Materials and Cavity Designs: Marginal Gap and Microleakage

Pages 3475-3790
Khaled Elbanna; Ahmed Zidan; Nada Abd Al-aleem

20.

Influence of Different Marginal Preparation Designs and Materials on the Marginal Integrity and Internal Adaptation of Endocrown Restorations

Pages 3491-3500
Samra AL-Zomur; Manal Abo-Madina; Mahy Hassouna

21.

Evaluation of peri-implant and posterior bone loss in rigid versus non-rigid telescopic attachments in two-implant supported mandibular overdenture

Pages 3501-3508
Diana Khalil; Emad Agamy; Gihan Mohammed

22.

RADIOGRAPHIC EVALUATION OF THE EFFECT OF IMPLANT SUPPORTED AND IMPLANT RETAINED DISTAL EXTENSION REMOVABLE PARTIAL DENTURES ON THE SUPPORTING STRUCTURES

Pages 3509-3517
Ragia Saad Kotb; Ahmed Ahmed Hassan; Emad Agamy; Gihan Mohammed

23.

Effect of different mechanical surface treatments on bond strength of acrylic teeth to polyamide denture base

Pages 3519-3523
Alaa Soliman; Mohamed Elgendy; Mohamed El-Sheikh

24.

Retention and Wear Characteristic Assessment of OT Equator with Smart Box Attachment Versus Ball Attachment for Mandibular Two Implant Assisted Over Denture. In-vitro Study

Pages 3525-3532
Doaa Rostom; Nourhan Ahmed Ragheb

25.

Biologic and prosthetic complications with two versus four mini-implants supporting mandibular overdentures in patients with knife edge ridges. One-year results of randomized controlled clinical trial

Pages 3533-3545
Ramy Moustafa Ali; Mohamad Helmy

26.

MARGINAL ADAPTATION AND FRACTURE RESISTANCE OF ENDOCROWN RESTORATIONS CONSTRUCTED FROM TWO CAD/CAM BLOCKS.

Pages 3547-3560
Amira Elsharkawy

27.

Effect of Diode Laser irradiation on the Bond Strength of Fiber Posts after Endodontic Retreatment Using Different Sealers.

Pages 3561-3578
Amira Elsharkawy

28.

The Accuracy Of Digital Versus Conventional Open Tray Implant Impression Technique, In Partially Edentulous Patients.

Pages 3579-3585
MOHAMED ABDALLA; Mohamed Dohiem

29.

Accuracy of digital impression technique versus conventional technique for completely edentulous patient: a controlled clinical trial.

Pages 3587-3594
Mohamed dohiem

30.

Effect of Locator Attachments with Different Retentive Insert Materials on Peri-implant Tissue Health in Mandibular Implant Overdenture

Pages 3595-3601
Alaa Elazaly; Salah Hegazy; Ahmed Salem; Mohamed Said

31.

Two canine tooth supported overdenture with ready-made attachments (3 year prospective study)

Pages 3603-3616
Ehab Elsaih; Bassant Mowafey

32.

Effect Of Repeated Heat Pressing And Thermocycling On Micro Shear Bond Strength Of Polyetheretherketone (PEEK) To Resin Cement

Pages 3617-3627
Ahmed Arafa; Marwa Emam

33.

A randomized controlled trial of ball and socket vs O-ring attachments for single implant-retained mandibular overdentures. A study of crestal bone loss and patient satisfaction

Pages 3629-3641
Dina El talawy

34.

Antifungal Action of Thyme and Basil Extracts on Different Denture Base Materials

Pages 3643-3650
kowkb eltamimi; Sara mohamed

35.

The impact of different cleaning protocols on resin bond strength to polymer-infiltrated ceramic material

Pages 3651-3662
Shaimaa Abo El-Farag